Conference Abstract
Tuncali, K., Tokuda J., Iordachita I., Song S. Sang- Eun, Fedorov A., Oguro S., et al. (2011).  3T MRI-guided Transperineal Targeted Prostate Biopsy: Clinical Feasibility, Safety, and Early Results. ISMRM 2011. 19, 53.PDF icon tuncali2011.pdf (380.57 KB)
Fritz, J., U-Thainual P., Ungi T., Flammang A. J., Fichtinger G., Iordachita I., et al. (2012).  Augmented Reality Visualization Using Image-Overlay for MR-guided Interventions: Performance Assessment of Paravertebral Sympathetic Perineural Injections in Cadavers at 1.5 Tesla. CARS 2012 Computer Assisted Radiology and Surgery. S509-S511.PDF icon 227A_Abstract_Fritz.pdf (78.1 KB)
Fritz, J., U-Thainual P., Ungi T., Flammang A. J., Cho N. Bongjoon, Fichtinger G., et al. (2011).  Augmented reality visualization using image-overlay for MR-guided interventions: assessment of accuracy for lumbar spinal procedures with a 1.5-Tesla MRI scanner. CIRSE 2011.
Song, S. Sang- Eun, Cho N. Bongjoon, Iordachita I., Fischer G., Tokuda J., Hata N., et al. (2010).  Development of a Pneumatic Robot for MRI-Guided Transperineal Prostate Intervention. Proc. of International Society for Magnetic Resonance in Medicine (ISMRM 2010). PDF icon Song2010b.pdf (165.71 KB)
U-Thainual, P., Fritz J., Cho N. Bongjoon, Ungi T., Segundo AJM., Carrino J. A., et al. (2010).  Evaluation of accuracy and clinical feasibility of the MR-compatible image overlay. 8th Interventional MRI Symposium. PDF icon 8th Interventional MRI Symposium_Abstract_paweena.pdf (200.26 KB)PDF icon 8th_iMRI_poster_paweena_Final.pdf (1.71 MB)
U-Thainual, P., Fritz J., Ungi T., Carrino J. A., Fichtinger G., & Iordachita I. (2013).  MR Image Overlay Adjustable Plane System for Musculoskeletal Interventions. ImNO2013 - Imaging Network Ontario Symposium. PDF icon Paweena_Abstract_ImNO2013.pdf (150.88 KB)PDF icon ImNO-2013-IOAPS-Final_0.pdf (1.62 MB)
U-Thainual, P., Ungi T., Carrino J. A., Fichtinger G., & Iordachita I. (2011).  MR Image Overlay Adjustable Plane System for Percutaneous Musculoskeletal Interventions. 4th NCIGT and NIH Image Guided Therapy Workshop. 4, PDF icon IGTworkshop2011_MR_IOAPS_poster_abstract_paweena.pdf (30.44 KB)
U-Thainual, P., Fritz J., Moonjaita C., Ungi T., Flammang A. J., Carrino J. A., et al. (2012).  MR Image Overlay Guidance: System Evaluation for Clinical Use. CARS 2012 Computer Assisted Radiology and Surgery. S179-S180.PDF icon LE-477A_UThainual_Paweena.pdf (307.26 KB)
Song, S. Sang- Eun, Cho N. Bongjoon, Tokuda J., Hata N., Tempany C. M., Fichtinger G., et al. (2010).  MRI compatibility study of a pneumatically actuated robotic system for transperineal prostate needle placement. CARS 2010 - Proceedings of the 24th International Congress and Exhibition. Int J CARS Vol 5 (Suppl 1), 26-27.PDF icon Song2010_0.pdf (388.9 KB)
Song, S. Sang- Eun, Cho N. Bongjoon, Tokuda J., Hata N., Tempany C. M., Fichtinger G., et al. (2010).  MRI compatibility study of a pneumatically actuated robotic system for transperineal prostate needle placement. 3rd Annual Image-Guided Therapy Workshop.
Song, S. Sang- Eun, Cho N. Bongjoon, Iordachita I., Guion P., Fichtinger G., & Whitcomb L. L. (2011).  Needle Artifact Localization for Intraprocedural Biopsy Position Confirmation in 3T MRI-guided Robotic Transrectal Prostate Intervention. 4th NCIGT and NIH Image Guided Therapy Workshop. 4,
Tokuda, J., Song S. Sang- Eun, Fischer G., Iordachita I., Seifabadi R., Cho N. Bongjoon, et al. (2012).  Preclinical evaluation of MRI-compatible pneumatic robot for angulated needle placement in prostate interventions. Computer-assisted Radiology and Surgery (CARS 2012). PDF icon 10.1007_s11548-012-0750-1.pdf (825.17 KB)
Tokuda, J., Tuncali K., Iordachita I., Song S. Sang- Eun, Fedorov A., Oguro S., et al. (2011).  Preliminary Accuracy Evaluation of 3T MRI-guided Transperineal Prostate Biopsy with Grid Template. ISMRM 2011 - 3rd Place Poster Award. 19, 3761.PDF icon tokuda2011.pdf (448.2 KB)
Seifabadi, R., Gomez E. Escobar, Aalamifar F., Fichtinger G., & Iordachita I. (2013).  Real-Time 3D Needle Shape Tracking Using Fiber Bragg Grating Sensors for Prostate Percutaneous Interventions. Image-guided Therapy (IGT) Workshop. PDF icon IGT Workshop 2013 Reza Seifabadi.pdf (149.32 KB)
Gomez, E. Escobar, Seifabadi R., Fichtinger G., & Iordachita I. (2012).  Real-time needle tip tracking using Fiber Brag Grating sensors for MRI-guided prostate interventions: Design considerations. 9th Interventional MRI Symposium (IMRI 2012). PDF icon Abstract_Esteban_final_6.pdf (91.28 KB)
Song, S. Sang- Eun, Seifabadi R., Krieger A., Tokuda J., Fichtinger G., & Iordachita I. (2011).  Robotic System for MRI-guided Prostate Intervention: Feasibility Study of Tele-operated Needle Insertion. Computer Aided Radiology and Surgery (CARS). PDF icon CARS 2011 Abstract.pdf (258.75 KB)
Song, S. Sang- Eun, Cho N. Bongjoon, Iordachita I., Guion P., Fichtinger G., & Whitcomb L. L. (2011).  A study of needle image artifact localization in confirmation imaging of MRI-guided robotic prostate biopsy. 2011 IEEE International Conference on Robotics and Automation (ICRA). 4834 - 4839.PDF icon Song2011d.pdf (1.07 MB)
U-Thainual, P., Iordachita I., Vikal S., & Fichtinger G. (2009).  Teaching Aid for Computer-Assisted Surgery. Eastern Ontario Symposium for Educational Technology. PDF icon EOSET2009_The Perk Station abstract.pdf (303.71 KB)
Seifabadi, R., Iordachita I., & Fichtinger G. (2012).  Towards teleoperated needle steering in MRI-guided prostate interventions. 9th Interventional MRI Symposium (IMRI 2012). PDF icon Abstract_Reza_Final_1.pdf (55.1 KB)
Conference Paper
Krieger, A., Iordachita I., Metzger G., Guion P., Atalar E., Fichtinger G., et al. (2006).  Accuracy of Hybrid Tracking for a Novel MR-Guided Transrectal Prostate Interventional Device. 6th Interventional MRI Symposium. 143-145.
Fritz, J., U-Thainual P., Ungi T., Flammang A. J., Cho N. Bongjoon, Fichtinger G., et al. (2011).  Augmented Reality Visualization Using Image-overlay for MR-guided Interventions: Assessment of Performance in Cadaveric Shoulder and Hip Arthrography. RSNA 97th Scientific Assembly and Annual Meeting. PDF icon 254.full_.pdf (1014.02 KB)
Jain, A. K., Deguet A., Iordachita I., Blevins J., Yi L., Armour E., et al. (2007).  C-arm based Intra-operative Dosimetry in Prostate Brachytherapy. Annual Meeting of the American Association of Physicists in Medicine (AAPM).
Kazanzides, P., Song D. Y., Fiene J., E. Burdette C., Kronreif G., Ptacek W., et al. (2008).  Clinical Trials of a Robot Assistant for Ultrasound-Guided Prostate Brachytherapy. Abstract in Minimally Invasive Therapy, 20th International Conference of the Society for Medical Innovation and Technology (SMIT). 14, 213.
Iordachita, I., Wiard R., Fichtinger G., Sakuma I., & Stoianovici D. (2004).  Controllable motorized devices for accurate percutaneous needle placement in soft tissue target. The Eleventh World Congress in Mechanism and Machine Science. 82-86.PDF icon Iordachita2004.pdf (1.8 MB)
Krieger, A., Iordachita I., Csoma C., Fichtinger G., & Whitcomb L. L. (2008).  Design and Preliminary Clinical Studies of an MRI-Guided Transrectal Prostate Intervention System. 7th International Symposium on Interventional MRI. 6-10.